Preview of the ACC: Percutaneous Mitral Valve Repair

"[The procedure is] very new and involves repairing my leaky valve using a clip device, without open heart surgery, so that my heart will function better"

-Elizabeth Taylor, via Twitter 6 Oct 2009
Percutaneous mitral valve repair will be the talk of the ACC Scientific Sessions for interventional cardiology this year, especially since coronary artery stent procedures are so, well, yesterday.

One valve repair technology popularized by Ms. Taylor's tweet that corrects a leaky mitral valve will be presented Sunday morning at the ACC meeting in Atlanta when the EVEREST II trial results are released (Larry Husten over at Cardiobrief.org has a nice outline of the late-breaking clinical trial schedule).

The EVEREST II trial is a phase 3 trial that compares the percutaneous mitral valve repair head-to-head with more conventional open mitral-valve surgery. The trial is sponsored by E-valve, Inc. (bought a year ago by Abbott). Since our center has participated in the trial (note to SEC: I have no clue about the results), it might be interesting to review the background and provide a few pictures on the technology. (By the way, this was NOT Elizabeth Taylor's procedure!)

(Important disclaimer: This device is NOT YET APPROVED for use in the US. Further, I have no financial interest in the manufacturer(s) and was not an investigator for the EVEREST I or EVEREST II trials, but I do work at one of the trial centers).

Background

In 1998, a report of correcting mitral valve insifficiency (leakage) was reported by Ottavio Alfieri and colleagues in the European Journal of Cardiovascular Surgery describing a technique to plicate (suture together) the mid-portion of the mitral valve, effectively creating a "bowtie" orifice to correct the leakage:
The experimental technique reported in this study could permit minimally invasive correction of the mitral insufficiency. These patients are often not referred for surgical repair, because they are believed “too sick” for conventional surgery. The experimental technology described in this report would avoid cardiopulmonary bypass and its consequences, and thus represents a more palatable alternative for these patients.
The long-term results of this technique were favorable and lead to the development of a minimally-invasive (yet transthoracic) approach for this same repair and later, thanks to the wonders of clever engineers, a completely percutaneous approach using a clip instead of sutures.

Equipment

(Note: Thanks to Dr. Ted Feldman for use of these great pictures) and the clinical trial nurses who make this all possible.

While minimally invasive, this procedure takes a village, so to speak, to perform: the interventional cardiologists, an echocardiographer and a well-hidden anesthesiologist (can you say "Where's Waldo?") barely seen behind the plastic drapes above the patient's head (yes, the patient gets to sleep for the procedure):

The personnel and equipment required to perform percutaneous repair of the mitral valve as viewed from the patient's feet. Note the Frankenstein-like steering-and-release contraption with all the IV tubing coming from it in front of the doctors used to place the mitral clip.
(Click image to enlarge)


A view from behind the implanting physicians. Note that all eyes are on the echocardiographic images to the right as the clip is positioned, rather than the fluroscopic images immedicately in front of the operators.
(Click image to enlarge)


The back end of the catheter delivery system looks just a bit complicated, since it steers the clip, grasps each leaflet of the mitral valve, and releases the clip when seated properly:


Click image to enlarge


The business end of the device is a small mechanical clip that grasps the center of the posterior and anterior leaflets of the mitral valve in an attempt to replicate the "bowtie" surgical repair originally described:


A cartoon rendition (top) and a photo of the clip (bottom) used to clip together the leaflets of the mitral valve


While the fluoro images of the procedure are interesting to view as the device is deployed:

An RAO fluoroscopic view of the mitral valve clip passed to the left atrium above the mitral valve.


The mitral valve clip is advanced below the mitral valve into the left ventricle in preparation of grasping the mitral valve.


The valve leaflets are grasped and the side "wings" of the clip closed.


The clip is deployed and fixes permanently to the mitral valve leaflets.


Although these fluoroscopic images are amazing, this procedure would not be possible without the ability to see the valve leaflets in realtime using transesophageal echocardiography:

Transesophageal echocardiographic images of the clip (outlined in orange) being placed below the mitral valve leaflets.


The clip is withdrawn until the leaflets of the mitral valve are engaged in the clip. (Note the "wings" of the clip are still open)


The wings of the clip are closed tightly to grasp the valve leaflets.


Will the Device Work?

Although preliminary results of the EVEREST I trial were promising, the EVEREST II trial will be the pivotal comparative effectiveness study comparing this approach to open mitral valve repair.

One thing's for sure after seeing all this: innovation in cardiology is alive and well!

See you Sunday!

-Wes

Tuesday, October 06, 2009

Elizabeth Taylor To Get E-Valve Mitral Valve Clip

As reported by E! online, it seems Elizabeth Taylor has significant mitral regurgitation (a leaky mitral valve) and will be undergoing an experimental Evalve MitraClip® mitral valve clipping procedure:
The two-time Oscar winner announced on Twitter today that she's checking into a hospital for a heart procedure. But don't worry—she predicts she'll be back on her feet in no time.

"[The procedure is] very new and involves repairing my leaky valve using a clip device, without open heart surgery, so that my heart will function better," tweeted Taylor.

"Any prayers you happen to have lying around I would dearly appreciate. I'll let you know when it's all over. Love you, Elizabeth."
The initial EVEREST I trial reported in the Journal of the American College of Cardiology on the first 24 patients receiving the device showed four 30-day major adverse events: partial clip detachment in three patients, who underwent elective valve surgery, and one patient with post-procedure stroke that resolved at one month. Three additional patients had surgery for unresolved MR, leaving 18 patients free from surgery.

More recent data on 107 patients in the US are summarized in a company press report and reported at this year's Transcatheter Cardiovascular Theraputics conference suggest favorable results with seventy-four percent of patients achieved MR reduction to 2+ or less and in 64 percent of these, MR reduction to 1+ was achieved. Additionally, there were no cases of clip embolization or procedural mortality reported. Kaplan-Meier freedom from surgery was 88.5%, 83.2% and 76.3% at 1, 2 and 3 years, respectively.

Hopefully for Ms. Taylor, things will work just as well for her.

-Wes

Disclosure: I have no commercial interest in the MitraClip device.

Addendum: Early reports suggest she did fine.

Tuesday, January 15, 2008

New Innovation for Mitral Regurgitation

File this under "What Will They Think of Next?"

For many individuals suffering from severe leakage of the mitral valve (mitral insufficiency) secondary to an enlarged left ventricle (dilated cardiomyopathy), surgical options are limited, especially in the setting of an individual with reduced left ventricular function. Repairing or replacing mitral valves in this setting risks exposing the left ventricle to increased wall stress following the repair with further dilation of the ventricular pumping chamber, leading to the rapid development of refractory heart failure.

So it is with interest that I noticed a new experimental technology introduced to our group yesterday which is about to begin clinical trials at our institution. This device uses a minimally invasive, percutaneous pericardial approach that applies a device that squeezes together the left ventricular walls beneath the mitral leaflets and maintains this force by way of a subvalvular cord passed through the heart walls and held on place by two epicardial pads on the outside surface of the heart. It is hoped that this technology would improve mitral valve closure while limiting the progressive dilation of the left ventricle.

The iCoapsys device is manufactured by Myocor, Inc of Maple Grove, Minnesota. It is percutaneously installed through a small incision beneath the lower portion of the sternum via the pericardial space. As such, prior open heart surgery would be a contraindication to implantation of this device due to scaring inherent to the pericarial area following surgery that would preclude easy installation of the device. iCoapsys it is a later generation version of their Coapsys device that can be installed during open heart surgery.

So for all the techies out there, here's a brief overview of this device:

How Is It Implanted?

First, a small puncture is made just beneath the lower border of the sternum using a special tool to enter the pericardial sac that lies over the heart:



Next, a guidewire is passed through the pericardial puncture device into the pericardial space over the heart:



Then,a larger dilator and sheath are passed over the guidewire into the pericardial space.



Other catheters are placed through the large staging sheath:



The posterior pad is passed over the posterior catheter:



The anterior pad is placed over the alternate catheter:



The two are aligned in the proper location using fluoroscopy and a special fluoroscopic "targeting" tool. A puncture of the left ventricle is performed and a wire enters the left ventricular chamber which is snared by a basket snare entering from the anterior approach:



Once snared, the cord is drawn taught until mitral insufficiency is diminished and left ventricular function can be assessed:



Once deployed, the percutaneous equipment is removed:



Now, the feasibility trial of this minimally invasive approach is about to get underway by Dr. Ted Feldman, who is the principle investigator at Evanston Northwestern Healthcare here in Chicago. Whether this works or not is uncertain, especially since the cord is likely to tether a portion of the right ventricle as well (and might restrict proper right ventricular function), but the approach heralds a whole new array of pericardial innovations for the heart that are soon to appear on the horizon.

-Wes

Images courtesy Myocor and Ted Feldman, MD